Omnes Categoriae

S NX1 Tres Phasium Transformator Immersus in Oleum (30kVA~31500kVA)

  • Conspectus
  • Producta commendata

Per investigationem et applicationem novarum materiarum et novarum artium, necnon per continuam independentem innovationem, et per optimam designatio et continua melioratio ferri et involucrorum, finis diminutionis detrimentorum et soni consecutus est, requisita normae nationalis GB20025-2020 implens.

Praeterea, gradus soni decrementum est per 20% in comparatione cum actuali norma nationali JB/T10088-2016, et performance producti usque ad domesticum avancatum level pervenit.

Compared with the energy efficiency grade ll products, the energy efficiency grade l products have lower losses.

 

Exsequi normas

 

GB 1094-2013 《Transformator Potentiae》

GB 1094-2013 《Transformator potentie 》

GBT6451-2015 《Technici parametri et requisita transformeris oleo immersis》

GBT6451-2015 《Parametri technici et requirmenta transformatoris olei immersi 》

IEC 60076 《Transformator potentie 》

 

Typus descriptio

 

微信截图_20250317152531.jpg

 

Conditio servitii normalis

 

Sub altitudine millem metrum

Suprema temperatura ambientalis est +40 gradus Celsius

Suprema media temperatura diei est +20 gradus Celsius

Infima temperatura exterioris est -20 gradus Celsius

 

Parameter euismod

 

Capacitas nominata (KVA) Laminatio ferri electrici Alloy amorphum
Amor fatuae (W) Amor oneris (W) Amor fatuae (W) Amor oneris (W)
Dyn11/Yzn11 Yyno Dyn11/Yzn11 YymD
30 65 455 430 25 510 480
50 80 655 625 35 735 700
63 90 785 745 40 880 840
80 105 945 900 50 1060 1010
100 120 1140 1080 60 1270 1215
125 135 1360 1295 70 1530 1450
160 160 1665 1585 80 1870 1780
200 190 1970 1870 95 2210 2100
250 230 2300 2195 110 2590 2470
315 270 2760 2630 135 3100 2950
400 330 3250 3095 160 3660 3480
500 385 3900 3710 190 4380 4170
630 460 4460 250 5020
800 560 5400 300 6075
1000 665 7415 360 8340
1250 780 8640 425 9720
1600 940 10440 500 11745
2000 1085 13180 550 14000
2500 1280 13360 670 15450


Opus est Auxilio in Eligendo Rectum Transformator?

Dum NX1 Transmutator Immersus in Oleum Phasium Tres (30kVA~31500kVA) praebet praestantem operationem pro multis applicationibus, eligendo ideale transformator involvit considerandum varios factores ultra singulum model. Noster completus guide explicat omnia a generibus transformatoris et clavis specificitationibus ad selectionem criteria basata super tuis specificis necessitatibus.

Legere Nostrum Totum Guidam: Quomodo Eligere Rectum Electricum Transformator

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
WhatsApp
Nuntius
0/1000
inquisitio

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
WhatsApp
Nuntius
0/1000