- Conspectus
- Producta commendata
Haec series transformatorum immersorum in oleum transgreditur structuram planam traditionalem et adoptat structuram tridimensionalem tridentem symmetrice.
Circuitus magneticus ferri tridentis producti sunt penitus symmetrici, resistentia magnetica magna minuitur, et fluxus excitatorius ac amissio inanis significe diminuuntur.
Est transformer efficax et parco in consumptione energie qui traditales materiales utitur, sed minor strepitu operationis et structura compactiviori praeditus est.
Habebit praestantiam egregiam in conservando et minuendo consumum, pariter ac in parvam quantitatem materialem servando et in tutela ambientis.
Exsequi normas
GB 1094-2013 《Transformator potentie 》
GB 1094-2013 《Transformator potentie 》
GBT6451-2015 《Technici parametri et requisita transformeris oleo immersis》
GBT6451-2015 《Parametri technici et requirmenta transformatoris olei immersi 》
IEC 60076 《Transformator potentie 》
Typus descriptio

Conditio servitii normalis
Sub altitudine millem metrum
Suprema temperatura ambientalis est +40 gradus Celsius
Suprema media temperatura diei est +20 gradus Celsius
Infimum exterius calor est -25 gradus Celsius
Parameter euismod
| Capacitas nominata (KVA) | Genus voltagii | Vector group | Ammissio (W) | Praesens sine onere (%) | Tensio impedimentalis (%) | Fines dimensionum (LxLxH, mm) | Pondus(kg) | ||
| HV (kV) | BT (kV) | Amussis in vacuo (W) | Amor oneris (W) | ||||||
| 30 | 1110.5106 | 0.4 | Dyn11autYyno | 80 | 630/600 | 0.3 | 4 | 800x620x1100 | 300 |
| 50 | 100 | 910/870 | 0.24 | 840x640x1150 | 380 | ||||
| 80 | 130 | 1090/1040 | 0.22 | 980x670x1210 | 480 | ||||
| 100 | 150 | 1310/1250 | 0.21 | 1040x700x1230 | 540 | ||||
| 125 | 170 | 1580/1500 | 0.20 | 910x800x1260 | 590 | ||||
| 160 | 200 | 1890/1800 | 0.19 | 1110x970x1290 | 720 | ||||
| 200 | 240 | 2310/2200 | 0.18 | 1180x1020x1310 | 860 | ||||
| 250 | 290 | 2730/2600 | 0.17 | 1190x1030x1300 | 970 | ||||
| 315 | 340 | 3200/3050 | 0.16 | 1290x1120x1360 | 1170 | ||||
| 400 | 410 | 3830/3650 | 0.16 | 1280x1110x1410 | 1320 | ||||
| 500 | 480 | 4520/4300 | 0.16 | 1400x1210x1420 | 1490 | ||||
| 630 | 570 | 6200 | 0.15 | 4.5 | 1440x1250x1490 | 1910 | |||
| 800 | 700 | 7500 | 0.15 | 1540x1340x1520 | 2160 | ||||
| 1600x1420x1630 | 2550 | ||||||||
| 1000 | 830 | 10300 | 0.14 | ||||||
| 1250 | 970 | 12000 | 0.13 | 1680x1460x1730 | 3160 | ||||
| 1600 | 1170 | 14500 | 0.12 | 1780x1540x1810 | 3850 | ||||
Opus est Auxilio in Eligendo Rectum Transformator?
Dum S13 Tres Phasium Transformator Immersus in Oleum (30kVA~31500kVA) praebet praestantem operationem pro multis applicationibus, eligendo ideale transformator involvit considerandum varios factores ultra singulum model. Noster completus guide explicat omnia a generibus transformatoris et clavis specificitationibus ad selectionem criteria basata super tuis specificis necessitatibus.
Legere Nostrum Totum Guidam: Quomodo Eligere Rectum Electricum Transformator