- Conspectus
- Producta Commendata
Genus LMZJ1-0.66 transformatoris curris convenit ad usum intramuralis.
Id in circuitu curris alternantis adhiberi potest, ubi maxima voltage apparatus non superat 0.72KV et infra, oneris factor potestatis 0.8, et frequens ordinata 50Hz est pro mensura curris.
Id adhibetur pro mensura vel metatione energie electricae.
Productum est generis fundendi et installatur modo quo cum busbar fixatur.
Exsequere standardes
GB/T 20840《Transformer》
IEC 61869《Instrument transformers》
Conditio servitii normalis
Altitudo non superat 1000m.
Temperatura ambientalis pro usu transfusoris directi est: intra -5℃ ad 40℃.
Transformatorius utilisatur in interioribus, et reliqua considerata conditiones operationis sunt sicut sequitur:
a) Influentia radiationsolaris negligi potest.
b) Aer ambientis non habet manifestam pollutionem ex pulvere, fumo, aerebus corrosivis, vaporibus aut salibus.
c) Conditiones humidorum sunt sicut sequitur:
1) Valor medius humiditatis relativae mensuratae intra 24 horas non superat 95%.
2) Valor medius vaporis aquae pressurae in 24 horis non superat 2.2kPa.
3) Valor medius humiditatis relativae in uno mense non superat 90%.
4) Valor medius vaporis aquae pressurae in uno mense non superat 1.8kPa.
Parameter euismod
Numerus Moduli | Ratio praesens A | Exitus nominatus VA | Numerus conversionum per cor | |||
0.5 gradus | 0.5S gradus | 0.2 gradus | 0.2S gradus | |||
30 I | 2000\/5 | 2.5 | 2.5 | 2.5 | 2.5 | 1 |
2050\/5 | 5 | 5 | 5 | 5 | 1 | |
200\/5 | 5 | 5 | 5 | 5 | 1 | |
250\/5 | 5 | 5 | 5 | 5 | 1 | |
300\/5 | 5 | 5 | 5 | 5 | 1 | |
2050\/1 | 2.5 | 2.5 | 2.5 | 2.5 | 1 | |
200/1 | 5 | 5 | 5 | 5 | 1 | |
250/1 | 5 | 5 | 5 | 5 | 1 | |
300/1 | 5 | 5 | 5 | 5 | 1 | |
40 I | 2050\/5 | 2.5 | 2.5 | 2.5 | 1 | |
200\/5 | 5 | 5 | 5 | 5 | 1 | |
250\/5 | 5 | 5 | 5 | 5 | 1 | |
300\/5 | 5 | 5 | 5 | 5 | 1 | |
400/5 | 5 | 5 | 5 | 5 | 1 | |
2050\/1 | 2.5 | 2.5 | 2.5 | 1 | ||
200/1 | 5 | 5 | 5 | 5 | 1 | |
250/1 | 5 | 5 | 5 | 5 | 1 | |
300/1 | 5 | 5 | 5 | 5 | 1 | |
400\/1 | 5 | 5 | 5 | 5 | 1 | |
60 I | 400/5 | 5 | 5 | 5 | 5 | 1 |
500\/5 | 5 | 5 | 5 | 5 | 1 | |
600\/5 | 5 | 5 | 5 | 5 | 1 | |
400\/1 | 5 | 5 | 5 | 5 | 1 | |
500\/1 | 5 | 5 | 5 | 5 | 1 | |
600\/1 | 5 | 5 | 5 | 5 | 1 | |
80 I | 800\/5 | 10 | 10 | 10 | 5 | 1 |
1000/5 | 10 | 10 | 10 | 5 | 1 | |
1200\/5 | 10 | 10 | 10 | 5 | 1 | |
1500\/5 | 10 | 10 | 10 | 5 | 1 | |
600\/1 | 10 | 5 | 5 | 5 | 1 | |
750\/1 | 10 | 10 | 10 | 5 | 1 | |
800\/1 | 10 | 10 | 10 | 5 | 1 | |
1000\/1 | 10 | 10 | 10 | 5 | 1 | |
1200\/1 | 10 | 10 | 10 | 5 | 1 | |
1500\/1 | 10 | 10 | 10 | 5 | 1 | |
100 I | 1000/5 | 10 | 10 | 10 | 5 | 1 |
1200\/5 | 10 | 10 | 10 | 5 | 1 | |
1500\/5 | 10 | 10 | 10 | 5 | 1 | |
2000\/5 | 20 | 20 | 20 | 10 | 1 | |
750\/1 | 10 | 10 | 10 | 5 | 1 | |
800\/1 | 10 | 10 | 10 | 5 | 1 | |
1000\/1 | 10 | 10 | 10 | 5 | 1 | |
1200\/1 | 10 | 10 | 10 | 5 | 1 | |
1500\/1 | 10 | 10 | 10 | 5 | 1 | |
2000\/1 | 20 | 20 | 20 | 10 | 1 |