Omnes Categoriae

Transformatores in oleo mergitos

Pagina Principalis >  Products >  Transformatores >  Transformatores in oleo mergitos

S (13) -30~31500kVA Trifasciatus immersus in oleum transfusor

  • Conspectus
  • Producta Commendata

Haec series transformatorum immersorum in oleum transgreditur structuram planam traditionalem et adoptat structuram tridimensionalem tridentem symmetrice.

Circuitus magneticus ferri tridentis producti sunt penitus symmetrici, resistentia magnetica magna minuitur, et fluxus excitatorius ac amissio inanis significe diminuuntur.

Est transformer efficax et parco in consumptione energie qui traditales materiales utitur, sed minor strepitu operationis et structura compactiviori praeditus est.

Habebit praestantiam egregiam in conservando et minuendo consumum, pariter ac in parvam quantitatem materialem servando et in tutela ambientis.

 

Exsequi normas

 

GB 1094-2013 《Transformator potentie 》

GB 1094-2013 《Transformator potentie 》

GBT6451-2015 《Technici parametri et requisita transformeris oleo immersis》

GBT6451-2015 《Parametri technici et requirmenta transformatoris olei immersi 》

IEC 60076 《Transformator potentie 》

 

Typus descriptio

 

微信截图_20250319154339.jpg

 

Conditio servitii normalis

 

Sub altitudine millem metrum

Suprema temperatura ambientalis est +40 gradus Celsius

Suprema media temperatura diei est +20 gradus Celsius

Infimum exterius calor est -25 gradus Celsius

 

 

Parameter euismod

 

Capacitas nominata (KVA) Genus voltagii Vector group Ammissio (W) Praesens sine onere (%) Tensio impedimentalis (%) Fines dimensionum (LxLxH, mm) Pondus(kg)
HV (kV) BT (kV) Amussis in vacuo (W) Amor oneris (W)
30 1110.5106 0.4 Dyn11autYyno 80 630/600 0.3 4 800x620x1100 300
50 100 910/870 0.24 840x640x1150 380
80 130 1090/1040 0.22 980x670x1210 480
100 150 1310/1250 0.21 1040x700x1230 540
125 170 1580/1500 0.20 910x800x1260 590
160 200 1890/1800 0.19 1110x970x1290 720
200 240 2310/2200 0.18 1180x1020x1310 860
250 290 2730/2600 0.17 1190x1030x1300 970
315 340 3200/3050 0.16 1290x1120x1360 1170
400 410 3830/3650 0.16 1280x1110x1410 1320
500 480 4520/4300 0.16 1400x1210x1420 1490
630 570 6200 0.15 4.5 1440x1250x1490 1910
800 700 7500 0.15 1540x1340x1520 2160
1600x1420x1630 2550
1000 830 10300 0.14
1250 970 12000 0.13 1680x1460x1730 3160
1600 1170 14500 0.12 1780x1540x1810 3850