- Conspectus
- Producta Commendata
Transformator BH-1.0 I-typus idoneus est ad usum intus.
Id applicatur in circuitibus correntis alternativi, ubi maxima voltia instrumentorum non superat 1.0KV et infra, factor potentiæ oneris est 0.8, et frequentiæ ratæ sunt 50Hz et 60Hz, et adhibetur ad mensuram vel metationem cursus et energiæ electricæ.
Id instalitur per modum fixionis busbar aut fixionis tabulæ basalis.
Est fenestra in medio transfusoris praesentis, per quam singula busbar aut cablum transire potest.
Exsequere standardes
GB/T 20840《Transformer》
IEC 61869《Instrument transformers》
Typus descriptio
Conditio servitii normalis
Altitudo non superat 1000m.
Temperatura ambientalis pro usu transfusoris directi est: intra -5℃ ad 40℃.
Transformatorius utilisatur in interioribus, et reliqua considerata conditiones operationis sunt sicut sequitur:
a) Influentia radiationsolaris negligi potest.
b) Aer ambientis non habet manifestam pollutionem ex pulvere, fumo, aerebus corrosivis, vaporibus aut salibus.
c) Conditiones humidorum sunt sicut sequitur:
1) Valor medius humiditatis relativae mensuratae intra 24 horas non superat 95%.
2) Valor medius vaporis aquae pressurae in 24 horis non superat 2.2kPa.
3) Valor medius humiditatis relativae in uno mense non superat 90%.
4) Valor medius vaporis aquae pressurae in uno mense non superat 1.8kPa.
Parameter euismod
Numerus Moduli | Ratio praesens A | Exitus nominatus VA | Numerus conversionum per cor | ||||
1 ordo | 0.5 gradus | 0.5S gradus | 0.2 gradus | 0.2S gradus | |||
20 I | 75/5 | 2.5 | 1 | ||||
100/5 | 2.5 | 1 | |||||
30 I | 30/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 5 |
50/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 3 | |
75/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 2 | |
75/5 | 2.5 | 1 | |||||
100/5 | 2.5 | 1 | 1 | ||||
100/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 2 | |
150/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 1 | |
200\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
250\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
300\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
400/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
500\/5 | 5 | 5 | 1 | ||||
600\/5 | 10 | 10 | 1 | ||||
30/1 | 2.5 | 2.5 | 5 | ||||
50\/1 | 2.5 | 2.5 | 3 | ||||
75\/1 | 1 | 1 | |||||
75\/1 | 2.5 | 2.5 | 2 | ||||
100/1 | 2.5 | 1 | 12 | ||||
100/1 | 5 | 5 | |||||
150/1 | 2.5 | 2.5 | 1 | ||||
200/1 | 5 | 5 | 1 | ||||
250/1 | 5 | 5 | 11 | ||||
300/1 | 5 | 5 | |||||
50 I | 150/5 | 2.5 | 2.5 | 2.5 | 2.5 | 1 | |
200\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
250\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
300\/5 | 5 | 5 | 5 | 5 | 5 | 1 | |
400/5 | 5 | 5 | 5 | 5 | 5 | 1 | |
500\/5 | 10 | 10 | 5 | 5 | 5 | 1 | |
600\/5 | 10 | 10 | 5 | 5 | 5 | 1 | |
750\/5 | . | . | 10 | 10 | 5 | 1 | |
800\/5 | . | - | 10 | 10 | 5 | 1 | |
1000/5 | * | . | 10 | 10 | 5 | 1 | |
1200\/5 | * | . | 20 | 20 | 5 | 1 | |
1500\/5 | * | . | 20 | 20 | 10 | 1 | |
750\/5 | 10 | 10 | . | . | . | 1 | |
800\/5 | 10 | 10 | * | * | . | 1 | |
1000/5 | 10 | 10 | . | * | . | 1 | |
1200\/5 | 20 | 20 | . | * | . | 1 | |
1500\/5 | 20 | 20 | * | * | * | 1 | |
150/1 | 2.5 | 1 | |||||
200/1 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
250/1 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
300/1 | 5 | 5 | 5 | 5 | 5 | 1 | |
400\/1 | 5 | 5 | 5 | 5 | 5 | 1 | |
500\/1 | 10 | 10 | 5 | 5 | 5 | 1 | |
600\/1 | 10 | 10 | 5 | 5 | 5 | 1 | |
750\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
800\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
1000\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
1200\/1 | 20 | 20 | 20 | 20 | 5 | 1 | |
60 I | 200\/5 | 5 | 2.5 | 2.5 | 2.5 | 2.5 | 1 |
250\/5 | 5 | 5 | 2.5 | 2.5 | 2.5 | 1 | |
300\/5 | 5 | 5 | 5 | 5 | 2.5 | 1 | |
40D/5 | 5 | 5 | 5 | 5 | 5 | 1 | |
500\/5 | 10 | 10 | 5 | 5 | 5 | 1 | |
600/S | 10 | 10 | 5 | 5 | 5 | 1 | |
750\/5 | 10 | 10 | 10 | 10 | 5 | 1 | |
800\/5 | 10 | 10 | 10 | 10 | 5 | 1 | |
1000/5 | 10 | 10 | 10 | 10 | 5 | 1 | |
1200\/5 | 20 | 20 | 20 | 20 | 5 | 1 | |
1500\/5 | * | . | 20 | 20 | 10 | 1 | |
2000\/5 | * | . | 20 | 20 | 10 | 1 | |
1500\/5 | 20 | 20 | . | * | * | 1 | |
2000\/5 | 20 | 20 | * | * | * | 1 | |
200/1 | 5 | 1 | |||||
250/1 | 5 | 5 | 1 | ||||
300/1 | 5 | 5 | 5 | 5 | 1 | ||
400\/1 | 5 | 5 | 5 | 5 | 5 | 1 | |
500\/1 | 10 | 10 | 5 | 5 | 5 | 1 | |
600\/1 | 10 | 10 | 5 | 5 | 5 | 1 | |
750\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
800\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
1000\/1 | 10 | 10 | 10 | 10 | 5 | 1 | |
1200\/1 | 20 | 20 | 20 | 20 | 5 | 1 | |
1500\/1 | 20 | 20 | 20 | 20 | 10 | 1 |