BH-1.0 I-turli jarayon transformatori ichki qulbi uchun mo'ljallangan.

U 1.0KV va undan past bo'lgan maksimal tashqi voltajdagi almashin chorreklarda ishlatiladi, yuk quvvati 0.8 ga teng va nomerlangan chastotalar 50Hz va 60Hz bo'lib, joriy va elektr energiya o'lchovlari uchun ishlatiladi.

U busbar yoki asosiy pleyta orqali sabablantirish usuli bilan o'rnatiladi.

Jarayon transformatorining o'rtasida bir dona busbar yoki kabel o'tishi mumkin bo'lgan oyna mavjud.

 

Standartlarni bajarish

 

GB⁄T 20840«Transformer»

IEC 61869«Ijroiy transformatorlar»

 

Turi ta'rifi

 

1.jpg

 

Oddiy ish sharoiti

 

Eng yuqori balandlik 1000m dan oshmaydi.

Joriy transformator ishlatish uchun muhit harorati: uy ichida -5℃ dan 40℃ gacha.

Joriy transformator uy ichida ishlatiladi va boshqa ko'rsatilgan ish shartlari quyidagilar:

a) Qo'shimcha sur'katcha radiatsiyasining ta'siri e'tiborsiz qilib olinishi mumkin.

b) Yuqori havo ayrimi, qatorli tozalikka ega emas, tozalikka, yong'ina, korroziv gazlarga, bukmalarga yoki tuzlarga ega emas.

c) Namlik shartlari quyidagicha:

1) 24 soat ichida o'lchangan nisbiy namlikning o'rtacha qiymati 95% dan oshmaydi.

2) 24 soat ichida suv bukmasining bosimining o'rtacha qiymati 2.2kPa dan oshmaydi.

3) Bir oy ichida nisbiy namlikning o'rtacha qiymati 90% dan oshmaydi.

4) Bir oy ichida suv bukmasining bosimining o'rtacha qiymati 1.8kPa dan oshmaydi.

 

Ишлаб чиқариш параметри

 

Model raqami Joriy nisbat A Nominal chiqish VA Yurak orqali burilgan turnlar soni
1-bazi 0.5 darajasi 0.5S daraja 0.2 daraja 0.2S daraja
20 I 75/5 2.5 1
100/5 2.5 1
30 I 30/5 5 2.5 2.5 2.5 2.5 5
50/5 5 2.5 2.5 2.5 2.5 3
75/5 5 2.5 2.5 2.5 2.5 2
75/5 2.5 1
100/5 2.5 1 1
100/5 5 5 2.5 2.5 2.5 2
150/5 5 2.5 2.5 2.5 2.5 1
200/5 5 5 2.5 2.5 2.5 1
250/5 5 5 2.5 2.5 2.5 1
300/5 5 5 2.5 2.5 2.5 1
400/5 5 5 2.5 2.5 2.5 1
500/5 5 5 1
600/5 10 10 1
30/1 2.5 2.5 5
50/1 2.5 2.5 3
75/1 1 1
75/1 2.5 2.5 2
100/1 2.5 1 12
100/1 5 5
150/1 2.5 2.5 1
200/1 5 5 1
250/1 5 5 11
300/1 5 5
50 I 150/5 2.5 2.5 2.5 2.5 1
200/5 5 5 2.5 2.5 2.5 1
250/5 5 5 2.5 2.5 2.5 1
300/5 5 5 5 5 5 1
400/5 5 5 5 5 5 1
500/5 10 10 5 5 5 1
600/5 10 10 5 5 5 1
750/5 . . 10 10 5 1
800/5 . - 10 10 5 1
1000/5 * . 10 10 5 1
1200/5 * . 20 20 5 1
1500/5 * . 20 20 10 1
750/5 10 10 . . . 1
800/5 10 10 * * . 1
1000/5 10 10 . * . 1
1200/5 20 20 . * . 1
1500/5 20 20 * * * 1
150/1 2.5 1
200/1 5 5 2.5 2.5 2.5 1
250/1 5 5 2.5 2.5 2.5 1
300/1 5 5 5 5 5 1
400/1 5 5 5 5 5 1
500/1 10 10 5 5 5 1
600/1 10 10 5 5 5 1
750/1 10 10 10 10 5 1
800/1 10 10 10 10 5 1
1000/1 10 10 10 10 5 1
1200/1 20 20 20 20 5 1
60 I 200/5 5 2.5 2.5 2.5 2.5 1
250/5 5 5 2.5 2.5 2.5 1
300/5 5 5 5 5 2.5 1
40D/5 5 5 5 5 5 1
500/5 10 10 5 5 5 1
600/S 10 10 5 5 5 1
750/5 10 10 10 10 5 1
800/5 10 10 10 10 5 1
1000/5 10 10 10 10 5 1
1200/5 20 20 20 20 5 1
1500/5 * . 20 20 10 1
2000/5 * . 20 20 10 1
1500/5 20 20 . * * 1
2000/5 20 20 * * * 1
200/1 5 1
250/1 5 5 1
300/1 5 5 5 5 1
400/1 5 5 5 5 5 1
500/1 10 10 5 5 5 1
600/1 10 10 5 5 5 1
750/1 10 10 10 10 5 1
800/1 10 10 10 10 5 1
1000/1 10 10 10 10 5 1
1200/1 20 20 20 20 5 1
1500/1 20 20 20 20 10 1