Genus LMZJ1-0.5 transformatoris tensionis aptum est ad usum intus.

Adhibetur ad mensuram vel computationem cursus et virium electricarum in circuitu cum alternante corrente, cuius maxima apparatus tensio est 0.72kV vel infra, factor oneris 0.8, et frequens nominata 50Hz.

Productum genus est casti vel typus injectionis glutinis thecae plasticae.

Installatur in modo affixionis eius ad tabulam basalem.

 

Exsequere standardes

 

GB/T 20840《Transformer》

IEC 61869《Instrument transformers》

 

Conditio servitii normalis

 

Altitudo non superat 1000m.

Temperatura ambientalis pro usu transfusoris directi est: intra -5℃ ad 40℃.

Transformatorius utilisatur in interioribus, et reliqua considerata conditiones operationis sunt sicut sequitur:

a) Influentia radiationsolaris negligi potest.

b) Aer ambientis non habet manifestam pollutionem ex pulvere, fumo, aerebus corrosivis, vaporibus aut salibus.

c) Conditiones humidorum sunt sicut sequitur:

1) Valor medius humiditatis relativae mensuratae intra 24 horas non superat 95%.

2) Valor medius vaporis aquae pressurae in 24 horis non superat 2.2kPa.

3) Valor medius humiditatis relativae in uno mense non superat 90%.

4) Valor medius vaporis aquae pressurae in uno mense non superat 1.8kPa.

 

Parameter euismod

 

Numerus Moduli Ratio praesens A Exitus nominatus VA Numerus conversionum per cor
0.5 gradus 0.5S gradus 0.2 gradus 0.2S gradus
30 I 5\/5 5 5 5 5 30
10\/5 5 5 5 5 15
15\/5 5 5 5 5 10
20\/5 5 5 5 5 10
25\/5 5 5 5 5 6
30/5 5 5 5 5 5
40/5 5 5 5 5 5
50/5 5 5 5 5 3
50/5 5 5 25 1
75/5 5 5 5 5 2
75/5 5 5 5 5 1
2000\/5 5 5 5 5 2
2000\/5 25 5 5 5 1
2050\/5 5 5 5 5 1
200\/5 5 5 5 5 1
250\/5 5 5 5 1
300\/5 5 5 5 5 1
5/1 2.5 2.5 2.5 2.5 30
10/1 2.5 2.5 2.5 2.5 15
15/1 2.5 2.5 2.5 2.5 10
20/1 5 5 5 5 10
25\/1 25 2.5 6
30/1 25 2.5 2.5 2.5 5
40\/1 5 5 5 5 5
50\/1 25 2.5 2.5 2.5 3
50\/1 1 1 1 1
75\/1 25 2.5 2.5 2
75\/1 1 1 1 1 1
2000\/1 5 5 5 5 2
2000\/1 2.5 2.5 2.5 2.5 1
2050\/1 25 2.5 2.5 2.5 1
200/1 5 5 5 5 1
250/1 5 5 5 5 1
300/1 5 5 5 5 1
50 I 400/5 5 5 5 5 1
500\/5 10 5 5 5 1
600\/5 10 5 5 5 1
400\/1 5 5 5 5 1
500\/1 10 5 5 5 1
600\/1 10 5 5 5 1
60 I 300\/5 5 5 5 5 1
400/5 5 5 5 5 1
500\/5 10 5 5 5 1
600\/5 10 5 5 5 1
750\/5 10 5 5 5 1
800\/5 10 5 5 5 1
300/1 5 5 5 5 1
400\/1 5 5 5 5 1
500\/1 10 5 5 5 1
600\/1 10 5 5 5 1
750\/1 10 5 5 5 1
800\/1 10 5 5 5 1
80 I *600/5 5 1
750\/5 10 10 10 5 1
800\/5 10 10 10 5 1
*1000/5 10 10 10 5 1
750\/1 10 10 10 5 1
800\/1 10 10 10 5 1
100 I 1000/5 10 10 10 5 1
1200\/5 10 10 10 10 1
1500\/5 10 10 10 10 1
*2000\/5 10 10 10 10 1
1000\/1 10 10 10 5 1
1200\/1 10 10 10 10 1
1500\/1 10 10 10 10 1
130 I 2000\/5 20 20 20 10 1
2500\/5 20 20 20 10 1
3000\/5 20 20 20 10 1
2000\/1 20 20 20 10 1
2500\/1 20 20 20 10 1
3000\/1 20 20 20 10 1
180 I 4000\/5 30 30 30 20 1
5000\/5 30 30 30 20 1
6000\/5 30 1
4000\/1 30 30 30 20 1
5000\/1 30 30 30 20 1