Barcha kategoriyalar

Past voltajdagi to'qim transformatorlari

Bosh sahifa >  Mahsulotlar >  Oqim transformatorlari >  Past voltajdagi to'qim transformatorlari

LMZJ1-0.5 Past To'qimli To'kimi O'zgaruvchi

  • Asosiy ma'lumot
  • Tavsiya etilgan mahsulotlar

LMZJ1-0.5 turli joriy o'zgaruvchan transformator uy ichida ishlatish uchun mo'ljallangan.

Bu, eng katta jihoz voltajining 0.72kV va undan past bo'lgan, yuk quvvati faktorining 0.8 va nomerlangan chastotingning 50Hz bo'lgan holda joriy va elektr energiya o'lchash yoki hisoblash uchun o'zgaruvchan joriy shakllarda ishlatilishi mumkin.

Maxsulot qayirat turida yoki plastik korpusdagi qayirat injektsiyasi turida.

U asos pleytga sabablantirish usuli bilan o'rnatiladi.

 

Standartlarni bajarish

 

GB⁄T 20840«Transformer»

IEC 61869«Ijroiy transformatorlar»

 

Oddiy ish sharoiti

 

Eng yuqori balandlik 1000m dan oshmaydi.

Joriy transformator ishlatish uchun muhit harorati: uy ichida -5℃ dan 40℃ gacha.

Joriy transformator uy ichida ishlatiladi va boshqa ko'rsatilgan ish shartlari quyidagilar:

a) Qo'shimcha sur'katcha radiatsiyasining ta'siri e'tiborsiz qilib olinishi mumkin.

b) Yuqori havo ayrimi, qatorli tozalikka ega emas, tozalikka, yong'ina, korroziv gazlarga, bukmalarga yoki tuzlarga ega emas.

c) Namlik shartlari quyidagicha:

1) 24 soat ichida o'lchangan nisbiy namlikning o'rtacha qiymati 95% dan oshmaydi.

2) 24 soat ichida suv bukmasining bosimining o'rtacha qiymati 2.2kPa dan oshmaydi.

3) Bir oy ichida nisbiy namlikning o'rtacha qiymati 90% dan oshmaydi.

4) Bir oy ichida suv bukmasining bosimining o'rtacha qiymati 1.8kPa dan oshmaydi.

 

Ишлаб чиқариш параметри

 

Model raqami Joriy nisbat A Nominal chiqish VA Yurak orqali burilgan turnlar soni
0.5 darajasi 0.5S daraja 0.2 daraja 0.2S daraja
30 I 5/5 5 5 5 5 30
10/5 5 5 5 5 15
15/5 5 5 5 5 10
20/5 5 5 5 5 10
25/5 5 5 5 5 6
30/5 5 5 5 5 5
40/5 5 5 5 5 5
50/5 5 5 5 5 3
50/5 5 5 25 1
75/5 5 5 5 5 2
75/5 5 5 5 5 1
2000/5 5 5 5 5 2
2000/5 25 5 5 5 1
2050/5 5 5 5 5 1
200/5 5 5 5 5 1
250/5 5 5 5 1
300/5 5 5 5 5 1
5/1 2.5 2.5 2.5 2.5 30
10/1 2.5 2.5 2.5 2.5 15
15/1 2.5 2.5 2.5 2.5 10
20/1 5 5 5 5 10
"Oʻzingizga yaxshilik qilinglar", 15. 25 2.5 6
30/1 25 2.5 2.5 2.5 5
40/1 5 5 5 5 5
50/1 25 2.5 2.5 2.5 3
50/1 1 1 1 1
75/1 25 2.5 2.5 2
75/1 1 1 1 1 1
2000/1 5 5 5 5 2
2000/1 2.5 2.5 2.5 2.5 1
2050/1 25 2.5 2.5 2.5 1
200/1 5 5 5 5 1
250/1 5 5 5 5 1
300/1 5 5 5 5 1
50 I 400/5 5 5 5 5 1
500/5 10 5 5 5 1
600/5 10 5 5 5 1
400/1 5 5 5 5 1
500/1 10 5 5 5 1
600/1 10 5 5 5 1
60 I 300/5 5 5 5 5 1
400/5 5 5 5 5 1
500/5 10 5 5 5 1
600/5 10 5 5 5 1
750/5 10 5 5 5 1
800/5 10 5 5 5 1
300/1 5 5 5 5 1
400/1 5 5 5 5 1
500/1 10 5 5 5 1
600/1 10 5 5 5 1
750/1 10 5 5 5 1
800/1 10 5 5 5 1
80 I *600/5 5 1
750/5 10 10 10 5 1
800/5 10 10 10 5 1
*1000/5 10 10 10 5 1
750/1 10 10 10 5 1
800/1 10 10 10 5 1
100 I 1000/5 10 10 10 5 1
1200/5 10 10 10 10 1
1500/5 10 10 10 10 1
*2000/5 10 10 10 10 1
1000/1 10 10 10 5 1
1200/1 10 10 10 10 1
1500/1 10 10 10 10 1
130 I 2000/5 20 20 20 10 1
2500⁄5 20 20 20 10 1
3000⁄5 20 20 20 10 1
2000/1 20 20 20 10 1
2500⁄1 20 20 20 10 1
3000⁄1 20 20 20 10 1
180 I 4000⁄5 30 30 30 20 1
5000⁄5 30 30 30 20 1
6000⁄5 30 1
4000⁄1 30 30 30 20 1
5000⁄1 30 30 30 20 1

Bezbosh xabar yuboring

Bizning ifodachisi tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Xabar
0/1000
inquiry

Bezbosh xabar yuboring

Bizning ifodachisi tez orada siz bilan bog'lanadi.
Email
Ism
Mobil/WhatsApp
Kompaniya nomi
Xabar
0/1000