- Conspectus
- Producta commendata
Ligamentum amorphum est novus genus materiae parservativae. Atomae metallicae in eo disponuntur in statu amorpho ordineque disordinato. Totum differt ab structura crystallina ferri silicei, et magis favet magnetizationi et demagnetizationi.
Crassitudo laminae nucleus ferri eius est nimis tenuis, tantummodo 0.025mm, quod est minus quam 1/10 illius laminae ferri silicei communis.
Hoc novum materiale, cum in nucleo ferroso transfusoris utitur, habet characteristicas intensitatis altae inductionis magneticae saturationis, bassae detrimenti, bassi currentis excitantis, et bonae stabilitatis temperature etc.
Exsequi normas
GB 1094-2013 《Transformator potentie 》
GB 1094-2013 《Transformator potentie 》
GBT6451-2015 《Technici parametri et requisita transformeris oleo immersis》
GBT6451-2015 《Parametri technici et requirmenta transformatoris olei immersi 》
IEC 60076 《Transformator potentie 》
Typus descriptio

Conditio servitii normalis
Sub altitudine millem metrum
Suprema temperatura ambientalis est +40 gradus Celsius
Suprema media temperatura diei est +20 gradus Celsius
Infimum exterius calor est -25 gradus Celsius
Parameter euismod
| Capacitas nominata (KVA) | Genus voltagii | Vector group | Ammissio (W) | Praesens sine onere (%) | Tensio impedimentalis (%) | Fines dimensionum (LxLxH, mm) | Pondus(kg) | ||
| HV (kV) | BT (kV) | Amussis in vacuo (W) | Amor oneris (W) | ||||||
| 30 |
11 10.5 6 |
0.4 |
Dyn11 an Yyno |
33 | 600 | 1.5 | 4 | 920x850x830 | 410 |
| 50 | 43 | 870 | 1.2 | 1040x780x870 | 520 | ||||
| 63 | 50 | 1040 | 1.1 | 1010x810x880 | 570 | ||||
| 80 | 60 | 1250 | 1.0 | 1060x830x910 | 640 | ||||
| 100 | 75 | 1500 | 0.9 | 1140x830x860 | 750 | ||||
| 125 | 85 | 1800 | 0.8 | 1110x880x950 | 830 | ||||
| 160 | 100 | 2200 | 0.6 | 1130x880x1000 | 940 | ||||
| 200 | 120 | 2600 | 0.6 | 1240x900x1020 | 1090 | ||||
| 250 | 140 | 3050 | 0.6 | 1290x900x1070 | 1250 | ||||
| 315 | 170 | 3650 | 0.5 | 1380x840x1110 | 1470 | ||||
| 400 | 200 | 4300 | 0.5 | 1420x920x1250 | 1710 | ||||
| 500 | 240 | 5150 | 0.5 | 4.5 | 1360x1040x1180 | 1990 | |||
| 630 | 320 | 6200 | 0.3 | 1530x1120x1310 | 2390 | ||||
| 800 | 380 | 7500 | 0.3 | 1880x1210x1360 | 2760 | ||||
| 1000 | 450 | 10300 | 0.3 | 2040x1520x1360 | 3240 | ||||
| 1250 | 530 | 12000 | 0.2 | 2140x1520x1430 | 3820 | ||||
| 1600 | 630 | 14500 | 0.2 | 2260x1540x1500 | 4620 | ||||
Opus est Auxilio in Eligendo Rectum Transformator?
Dum SH15 Tres Phases Oleum Immersus Transformer (30kVA~31500kVA) praebet praestantem operationem pro multis applicationibus, eligendo ideale transformator involvit considerandum varios factores ultra singulum model. Noster completus guide explicat omnia a generibus transformatoris et clavis specificitationibus ad selectionem criteria basata super tuis specificis necessitatibus.
Legere Nostrum Totum Guidam: Quomodo Eligere Rectum Electricum Transformator