- Overview
- Recommended Products
Amorphous alloy is a new type of energy-saving material. The metal atoms in it are arranged in a disordered amorphous state. It is completely different from the crystal structure of silion steel, and it is more conducive to magnetization and demagnetization.
The thickness of its iron core sheet is extremely thin, only 0.025mm,which is less than 1/10 of that of ordinary silicon steel sheets.
This new material, when used in the iron core of a transformer, has the characteristics of high saturation magnetic induction intensity, low loss, low exciting current, and good temperature stability,etc.
Enforce standars
GB 1094-2013 《Power Transformer 》
GB 1094-2013 《Power transformer 》
GBT6451-2015 《Oil immersed power transformer technicalparameters and requirements 》
GBT6451-2015 《Oil immersed power transformer technical parameters and requirements 》
IEC 60076 《Power transformer 》
Type description

Normal service condition
Below an altitude of 1000 meters
The highest ambient temperature is +40 degrees Celsius
The highest daily average temperature is +20 degrees Celsius
The lowest outdoor temperature is -25 degrees Celsius
Performance parameter
| Ratedcapacity(kVA) | Voltage group | Vector group | Loss(W) | No-loadcurrent(%) | Impedancevoltage(%) | Boundarydimension(LxWxH,mm) | Weight(kg) | ||
| HV(kV) | LV(KV) | No-load loss (W) | Load loss(W) | ||||||
| 30 |
11 10.5 6 |
0.4 |
Dyn11 or Yyno |
33 | 600 | 1.5 | 4 | 920x850x830 | 410 |
| 50 | 43 | 870 | 1.2 | 1040x780x870 | 520 | ||||
| 63 | 50 | 1040 | 1.1 | 1010x810x880 | 570 | ||||
| 80 | 60 | 1250 | 1.0 | 1060x830x910 | 640 | ||||
| 100 | 75 | 1500 | 0.9 | 1140x830x860 | 750 | ||||
| 125 | 85 | 1800 | 0.8 | 1110x880x950 | 830 | ||||
| 160 | 100 | 2200 | 0.6 | 1130x880x1000 | 940 | ||||
| 200 | 120 | 2600 | 0.6 | 1240x900x1020 | 1090 | ||||
| 250 | 140 | 3050 | 0.6 | 1290x900x1070 | 1250 | ||||
| 315 | 170 | 3650 | 0.5 | 1380x840x1110 | 1470 | ||||
| 400 | 200 | 4300 | 0.5 | 1420x920x1250 | 1710 | ||||
| 500 | 240 | 5150 | 0.5 | 4.5 | 1360x1040x1180 | 1990 | |||
| 630 | 320 | 6200 | 0.3 | 1530x1120x1310 | 2390 | ||||
| 800 | 380 | 7500 | 0.3 | 1880x1210x1360 | 2760 | ||||
| 1000 | 450 | 10300 | 0.3 | 2040x1520x1360 | 3240 | ||||
| 1250 | 530 | 12000 | 0.2 | 2140x1520x1430 | 3820 | ||||
| 1600 | 630 | 14500 | 0.2 | 2260x1540x1500 | 4620 | ||||
Need Help Choosing the Right Transformer?
While the SH15 Three Phase Oil Immersed Transformer(30kVA~31500kVA) offers excellent performance for many applications, selecting the ideal transformer involves considering various factors beyond a single model. Our comprehensive guide explains everything from transformer types and key specifications to crucial selection criteria based on your specific needs.